Mitigate "RTC Offline" When RDS Status is Full in BOSS HMI
Skill required to complete this article: Controls and level is No Skill Level Association.

Question/Problem
 
The BOSS HMI shows "RTC Offline" in the bottom right corner of the HMI.

 

 

Environment

  •  BOSS III

Answer/Solution

 
"RTC Offline" message will appear in the bottom right corner of the BOSS III HMI whenever the connected user has lost connection to the HMI; this is most frequently caused by too many users attempting to connect beyond the RDS capacity (could also be due to local network issue to user attempting connection). Often times associates will fail to exit the HMI when leaving for the day, or will open multiple instances of the HMI in order to see information side-by-side rather than tabbing between screens. A completely full RDS Status client list means that users will compete for HMI connection. Strange/unexplained issues can also happen with production as the controller communications become bogged down by excessive connected users. The number of users connected to the HMI can be seen under the RDS Status, typically under the Maintenance Menu.

Although it is not always effective for every site, it is often helpful to force the socket closed for HMI connection to the RTC. Forcing the socket closed can, for some sites, be effective in disconnecting inactive users. To force the socket closed in RDS status, select the RTC and right click to select "Force Socket Closed" on the drop-down menu. The socket will automatically reopen after it is forced closed. Each RTC has its own socket, so if multiple RTCs are throwing the "RTC Offline" message, then the socket for each RTC will need to be closed individually.

If forcing the socket closed is not effective, users will simply reconnect automatically and will need to be logged out of the HMI manually at the machine they are using to log in. Best practice for managing RDS connections is to remind associates to log out and exit the HMI at the end of the day, and to tab between screens rather than open multiple instances of BOSS HMI to view information side-by-side.

 

Related items

Internal Notes

Reason for confidentiality


DISCLAIMER:

Information in this document is subject to change without notice and does not represent a commitment on the part of Intelligrated. This information is typical of the questions and general advice given; however, your particular case and circumstances may produce different results or require different recommendations. Therefore, use of this information is not a suitable replacement for contacting Intelligrated Technical Service engineering for specific recommendations and solutions to your application.

 

No part of this article may be reproduced or transmitted in any form or by any means including recording, or information storage and retrieval systems, for any purpose without the express written permission of Intelligrated. All information contained within the article is private and confidential and the sole property of Intelligrated.

 

In no event, shall Intelligrated be liable for any damages whatsoever including, without limitation, damages for loss of business profits, business interruption, loss of business information, or other pecuniary loss, even if Intelligrated has been advised of the possibility of such damages. Because some states do not allow the exclusion or limitation of liability for consequential or incidental damages, the above limitation may not apply to you.

 

 Related Articles
No Related Articles Available.
 Article Info
 Article ID:  KB-10931
 Published on  7/2/2020
 Last Modified on  7/2/2020
 Last Modified by  Carolyn Pickering
 Original URL:  https://dashboard.intelligrated.com//Knowledgebase/Article.aspx?article=731e371e-50db-461e-9729-2192e4de175b
Close Window