Article: KB-11340
Fix:
No product being inducted to the PandA station
Skill required to complete this article: Peripheral ~ Printer and level is No Skill Level Association.

Related tickets

 TS-00407444

Question/Problem
 
No inducts to PandA station

Product stops before the print and apply station

Mechanical case-stop not allowing the tote to advance

  

Environment

PLC

IntelliQ Zone

Answer/Solution

i) Locate the photoeye that detects product in front of the stop (IntelliQ conveyors are divided into three-foot-long Zones, each zone has a photo-eye to detect product)

 

ii) Locate the solenoids that activates the brakes and the mechanical case-stops

 

iii) Tell site to flag the photoeyes. You should be able to see the value changing in the BOSS/ICW/PLC interface (This article is using PLC as an example). If you don't see the value changing in the photoeye, tell site to review connections or replace photoeye.

 

iv) Force and unforce the solenoids. Confirm with site if the case-stops are moving when forcing them. If case-stops are not moving when forcing, tell site to review electrical wiring connections and air pressure.

v) If you were able to see the photoeyes flagging and to force the solenoids you can discard input/output issues and power issues.

vi) Search for faults, jam alarms or full conditions on the downstream conveyors.

  -   If the downstream lanes are full, product will be held at the case-stop prior the print and apply area.

  - If full lane conditions or jam conditions were found, locate the photoeyes and tell site to flag them. If they don't flag, verify wiring connections or replace them. After clearing a jam, site needs to press the reset button to clear the alarm

  - Barcode scanner will scan the product and verify that a label has been appropriately applied (No reads from scanner could cause a Scanner Fault)

- If a scanner fault condition is found, clear the fault and tell site to release boxes to test the conveyor. If the scanner fault is raised again, review scanner connections and alignment. Review labels applied. Review barcodes info in the system BOSS/ICW/PLC

vii) Also verify site has the proper login permissions on the PandA PC. Because if not, the PandA station wont induct totes.

*** Example of scanner fault raised PLC Example ***

- Stop01 will not release because the "Panda_ExcessiveFaults" is activated.

- The Panda_ExcessiveFaults activates when the verification scanner doesn't read 7 or more barcodes

 

How does a Mechanical Case-Stop works? Youtube video

  https://www.youtube.com/watch?v=diePBoQPrLM

 Related Articles
No Related Articles Available.
 Help us improve this article...
What did you think of this article?
poor   excellent
Your Email:
Tell us why you rated the content this way. (optional)
RadEditor - HTML WYSIWYG Editor. MS Word-like content editing experience thanks to a rich set of formatting tools, dropdowns, dialogs, system modules and built-in spell-check.
RadEditor's components - toolbar, content area, modes and modules
   
Toolbar's wrapper 
 
Content area wrapper
RadEditor's bottom area: Design, Html and Preview modes, Statistics module and resize handle.
It contains RadEditor's Modes/views (HTML, Design and Preview), Statistics and Resizer
Editor Mode buttonsStatistics moduleEditor resizer
 
 
RadEditor's Modules - special tools used to provide extra information such as Tag Inspector, Real Time HTML Viewer, Tag Properties and other.
   
 

 Comments...
No user comments available for this article.
Published on 9/30/2022.
Last Modified on 11/27/2022.
Last Modified by Joe Lowry.
Article has been viewed 330 times.
Rated out 0 of 10 based on 0 votes.
Print Article Print Article
Print Article Email Article